Part of our available testing services
Part of our testing services are briefly introduced below.
AFM | BET | FTIR | IC (Ion Chromatography) | ICP-OES ICP-MS |
NMR (Liquid) NMR (Solid) | Organic Elements CHNS-O | Raman | SEM SEM-EDS | TEM TEM-EDS |
TG-DSC TGA / DSC | TPR TPD | XPS | XRF | XRD |
Contact us (Tel: 6611-9040; Email: sales@latech.com.sg) to find our more!
S/N | Testing Service | Remarks |
1 | AFM | • Equipment: Bruker Dimension Icon • Sample size: substrate > 5*5 mm, with flat surface • Total 6 scanning: 2 different locations*3 different magnifications • Original data provided for data analysis, such as 3D structure, height profile, etc. |
2 | BET | • Equipment model:
• Sample amount: powder > 1 g (carbon materials with large specific surface area can be > 0.2 g) • Testing in standard N2 atmosphere • Full set testing report with excel data • Extra services available:
|
3 | FTIR | • Equipment: Nicolet IS10, US • Sample amount: solution 3-5 mL, powder of red bean size • Wavenumber range: 400-4000 cm-1, corresponds to 25-2.5 um wavelength • Can test organic solution, solid samples • Cannot test aqueous solution • Extra services available:
|
4 | IC (Ion Chromatography) | • Equipment: Dionex ICS-1600, US • Sample amount: solution 3-5 mL • Can test: F, Cl, Br, NO2, NO3, SO4, PO4 • Cannot test: CO3, HCO3 |
5 | ICP-OES / ICP-MS | • Equipment: Agilent 720 for ICP-OES, Agilent 7700s for ICP-MS • Sample amount: solution 3-5 mL, powder >0.5 g, big bulk samples are difficult to digest • Detection limit: 20 ppb for ICP-OES, 1 ppb for ICP-MS • Extra services available:
|
6 | NMR (Liquid) | • Equipment: Bruker AVANCE III 600 • Sample amount: solution 3-5 mL • Standard testing of H/C spectra • Extra elements: B. P, F, Cl, Si, Al, Pb, Br |
7 | NMR (Solid) | • Equipment: Bruker AVANCE III 600 • Sample amount: powder >0.5 g • Standard testing of H/C spectra • Extra elements: B. P, F, Cl, Si, Al, Pb, Br |
8 | Organic element analyzer (CHNS-O) | • CHNS can be tested together, but O needs to be tested separated using different attachment • Sample amount: powder >0.1 g • Detection limit: 0.1 wt% • Need sample weight > 50 mg |
9 | Raman | • Laser sources: 325, 514, 532, 633, 785 nm • Sample size: substrate > 5*5 mm, powder of red bean size • Repeated scanning from 3 different locations |
10 | SEM | • Equipment: Hitachi SU8020 • Sample size: substrate > 5*5 mm, powder of red bean size • 10-15 images for each sample from 2 different locations • Extra services available:
|
11 | TEM | • Equipment: FEI Talos F200 • Sample requirements:
• Extra services available:
|
12 | TG-DSC (TGA and DSC) | • Equipment: Mettler Toledo TG-DSC 3+ • Sample amount: powder >0.1 g • Testing modes:
• Extra services available:
|
13 | TPR / TPD | • TPR in 5 vol% H2/N2 atmosphere • TPD in H2, CO2, NH3, as well as CO, NO, NO2 atmosphere • Sample amount: powder >0.5 g • Temperature range: RT – 950 °C |
14 | XPS | • Equipment: PHI-5400, Physical Electronics, US • Sample size: substrate > 5*5 mm, powder of red bean size • Extra services available:
|
15 | XRF | • Equipment: Shimadzu XRF-1800, with Rh X-ray tube • Sample size: powder 3-5 g, bulk < Dia 30 * Thickness 20 mm • Detection limit: 0.01 wt% (~100 ppm) • Cannot detect light elements before O (such as H, C, N, etc) • Provide results in elemental and oxide form |
16 | XRD | • Equipment: Bruker D8 ADVANCE • Sample amount: substrate > 10*10 mm, powder of red bean size • Standard conditions: 2θ range 5-90°, scanning rate 3°/min • Extra services available:
|
We have a wide range of other testing services available, such as UPS, UV-vis, EBSD, mechanical testing, nano-indentation, zeta potential, surface profiler, etc.